 34 pin IDC male connector at the controller
| The first drives used an encoding method called MFM (Modified Frequency Modulation). Later a new encoding method was developed, RLL (Run Length Limited). RLL had the advantage that it was possible to store 50% more with it. But it required better drives. This is almost never an problem. Often called 2,7 RLL because the recording scheme involves patterns with no more than 7 successive zeros and no less than two. Second connector: 20 PIN IDC MALE at the Controller.
 20 PIN IDC FEMALE at the Harddisk.
 Control connectorPin | Name | Description |
2 | | Head Sel 8 |
4 | | Head Sel 4 |
6 | | Write Gate |
8 | | Seek Complete |
10 | | Track 0 |
12 | | Write Fault |
14 | | Head Sel 1 |
16 | RES | (reserved) |
18 | | Head Sel 2 |
20 | | Index |
22 | | Ready |
24 | | Step |
26 | | Drive Sel 1 |
28 | | Drive Sel 2 |
30 | | Drive Sel 3 |
32 | | Drive Sel 4 |
34 | | Direction In |
Note: All odd pins are GND, Ground.Data connectorPin | Name | Description |
1 | | Drive Selected |
2 | GND | Ground |
3 | RES | (reserved) |
4 | GND | Ground |
5 | RES | (reserved) |
6 | GND | Ground |
7 | RES | (reserved) |
8 | GND | Ground |
9 | RES | (reserved) |
10 | RES | (reserved) |
11 | GND | Ground |
12 | GND | Ground |
13 | | Write Data+ |
14 | | Write Data- |
15 | GND | Ground |
16 | GND | Ground |
17 | | Read Data+ |
18 | | Read Data- |
19 | GND | Ground |
20 | GND | Ground |
This information should be correct, but may be not. Please, help us to improve this document! Is this document CORRECT or INCORRECT? Your opinion will be used to establish document status (showed at the bottom). |
|  34 pin IDC female connector at the harddisk
|